HT33 Series Tower Online UPS 60-500kVA (380V/400V/415V)

HT33 Series Tower Online UPS 60-500kVA (380V/400V/415V)

HT33 series three phase UPS offers advanced technology that increase performance and reliability: 3 high-speed DSPs (Digital Signal Processing) with completed digital control fully ensure high quality of power supply, high input power factor and low input current distortion. It also offers humanization design: full front access of serviceability and user friendly interface.

Request a quote

For fastest support.

Please call 1800 6567 (Free of charge)

The HT33 3-phase UPS series features advanced technology that enhances performance and reliability: 3 high-speed DSP (Digital Signal Processing) units with fully digital control for enhanced power quality. electricity. High input power factor, low current distortion. User-friendly design: full front-end functions and user-friendly interface.

00 +

YEARS OF EXPERIENCE

00 +

TALENTS

00 +

CUSTOMER

Detailed Product Description

Application:

  • IDC (Internet Data Center), ISP, IT Room, Service Center
  • Precision instruments, Intelligent equipment

Technical advantages:

  • High efficiency, up to 96%
  • High input PF = 1, low current distortion THDi
  • Muti-protection, over-temperature protection with 8 sensors, over-load, battery under voltage, fan failures, short-circuit.
  • Battery cold start
  • Battery management: smart charging control, auto maintenance, greatly extend the battery life
  • High power density
  • Parallel up to 1500kVA
  • Modular design of subsystem, convenient for field maintenance
  • Friendly operation interface, color touch LCD screen.

Request a quote

    MODEL HT33060X HT33080X HT33090X HT33100X HT33120X HT33150X HT33200X HT33250X HT33300X HT33400X HT33500X
    System Capacity 60kVA 80kVA 90kVA 100kVA 120kVA 150kVA 200kVA 250kVA 300kVA 400kVA 500kVA
    Input Dual Input Standard Optional Standard
    Phase 3 Phase+Neutral+Ground, 380V/400V/415V(line-line)
    Input Voltage Range 304~478Vac (line-line),full load;

    228V~304Vac (line-line),load decreases linearly according to the min phase voltage

    Rate Frequency 50/60Hz
    Input Frequency Range 40Hz~70Hz
    Input PF >0.99
    Input THDi <3% (100% Linear load)
    Bypass Rate Voltage 380/400/415Vac (line-line)
    Rate Frequency 50/60Hz
    Input Voltage Range Settable, -40%~+25%
    Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
    Bypass Overload 125% long term operation

    130% for 10 mins

    150% for 1 min

    >150% for 300ms

    110% long term operation

    125% for 5 mins

    150% for 1 min

    >150% for 1s

    Output Rate Voltage 380/400/415Vac (line-line)
    Voltage Regulation 1% for balance load; 1.5% for unbalance load
    Rate Frequency 50/60Hz
    Frequency Precision 0.1%
    Output PF 1
    Output THDu <1% , Linear load; <5.5%, Non-linear load
    Crest Factor 3:1
    Inverter Overload 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
    Battery Voltage ±240Vdc
    Battery Number 40pcs (Settable: even number from 32 to 44)
    Voltage Precision ±1%
    Charge Power up to 20% * Output active power
    Battery Cold Start Optional Standard
    System Efficiency AC Mode 95% 96% 95% 96% 95% 96%
    ECO Mode 99%
    Battery Mode 95% 96% 95% 96% 95% 96%
    Display 10.4″(240kVA-500kVA) or 7”(60kVA-200kVA) touch screen LCD + LED + keyboard
    IP Class IP 20
    Interface RS232,RS485, Programmable Dry Contact, USB
    Option SNMP Card, Parallel kit, SPD, LBS, Dust filter
    Temperature Operation: 0~40 ℃ Storge: -40~70 ℃
    Relative Humidity 0~95% Non-condensing
    Altitude <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise
    Noise (1 meter) 65dB @ 100% load, 62dB @ 45% load
    Applicable Standards Safety: IEC/EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3
    Physical Weight (kg) 170 210 231 210 266 305 350 445 490 810 900
    Dimension W*D*H (mm) 600*980*950 600*980*1150 600*980*1400 600*980*1150 600*980*1400 650*960*1600 650*960*1600 650*970*2000 650*970*2000 1300*1100

    *2000

    1300*1100

    *2000

    MODEL HT33060X HT33080X HT33090X HT33100X HT33120X HT33150X HT33200X HT33250X HT33300X HT33400X HT33500X
    System Capacity 60kVA 80kVA 90kVA 100kVA 120kVA 150kVA 200kVA 250kVA 300kVA 400kVA 500kVA
    Input Dual Input Standard Optional Standard
    Phase 3 Phase+Neutral+Ground, 380V/400V/415V(line-line)
    Input Voltage Range 304~478Vac (line-line),full load;

    228V~304Vac (line-line),load decreases linearly according to the min phase voltage

    Rate Frequency 50/60Hz
    Input Frequency Range 40Hz~70Hz
    Input PF >0.99
    Input THDi <3% (100% Linear load)
    Bypass Rate Voltage 380/400/415Vac (line-line)
    Rate Frequency 50/60Hz
    Input Voltage Range Settable, -40%~+25%
    Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
    Bypass Overload 125% long term operation

    130% for 10 mins

    150% for 1 min

    >150% for 300ms

    110% long term operation

    125% for 5 mins

    150% for 1 min

    >150% for 1s

    Output Rate Voltage 380/400/415Vac (line-line)
    Voltage Regulation 1% for balance load; 1.5% for unbalance load
    Rate Frequency 50/60Hz
    Frequency Precision 0.1%
    Output PF 1
    Output THDu <1% , Linear load; <5.5%, Non-linear load
    Crest Factor 3:1
    Inverter Overload 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
    Battery Voltage ±240Vdc
    Battery Number 40pcs (Settable: even number from 32 to 44)
    Voltage Precision ±1%
    Charge Power up to 20% * Output active power
    Battery Cold Start Optional Standard
    System Efficiency AC Mode 95% 96% 95% 96% 95% 96%
    ECO Mode 99%
    Battery Mode 95% 96% 95% 96% 95% 96%
    Display 10.4″(240kVA-500kVA) or 7”(60kVA-200kVA) touch screen LCD + LED + keyboard
    IP Class IP 20
    Interface RS232,RS485, Programmable Dry Contact, USB
    Option SNMP Card, Parallel kit, SPD, LBS, Dust filter
    Temperature Operation: 0~40 ℃ Storge: -40~70 ℃
    Relative Humidity 0~95% Non-condensing
    Altitude <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise
    Noise (1 meter) 65dB @ 100% load, 62dB @ 45% load
    Applicable Standards Safety: IEC/EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3
    Physical Weight (kg) 170 210 231 210 266 305 350 445 490 810 900
    Dimension W*D*H (mm) 600*980*950 600*980*1150 600*980*1400 600*980*1150 600*980*1400 650*960*1600 650*960*1600 650*970*2000 650*970*2000 1300*1100

    *2000

    1300*1100

    *2000