HOTLINE
This HT33-TX UPS applies advanced technology that increases performance and reliability: 2 high-speed DSPs (Digital Signal Processing) with completed digital control to ensure high quality of power supply, high input power factor and low input current distortion. With in-built transformers, the HT33-TX series offers greater safety for critical loads.
For fastest support.
Please call 1800 6567 (Free of charge)
| MODEL | HT33010XS | HT33015XS | HT33020XS | HT33030XS | HT33040XS | ||
| HT33010XL | HT33015XL | HT33020XL | HT33030XL | HT33040XL | |||
| System Capacity | 10kVA | 15kVA | 20kVA | 30kVA | 40kVA | ||
| Input | Dual Input | Standard | |||||
| Phase | 3 Phase+Neutral+Ground, 380V/400V/415V(line-line) | ||||||
| Input Voltage Range | 304~478Vac (line-line),full load;
228V~304Vac (line-line),load decreases linearly according to the min phase voltage |
||||||
| Rate Frequency | 50/60Hz | ||||||
| Input Frequency Range | 40Hz~70Hz | ||||||
| Input PF | >0.99 | ||||||
| Input THDi | <4% (100% Linear load) | <3% (100% Linear load) | |||||
| Bypass | Rate Voltage | 380/400/415Vac (line-line) | |||||
| Rate Frequency | 50/60Hz | ||||||
| Input Voltage Range | Settable, -40%~+25% | ||||||
| Bypass Frequency Range | Settable, ±1Hz, ±3Hz, ±5Hz | ||||||
| Bypass Overload | 125% long term operation; 130% for 10 mins; 150% for 1 min | ||||||
| Output | Rate Voltage | 380/400/415Vac (line-line) | |||||
| Voltage Regulation | 1% for balance load; 1.5% for unbalance load | ||||||
| Rate Frequency | 50/60Hz | ||||||
| Frequency Precision | 0.1% | ||||||
| Output PF | 1 | 0.9 | |||||
| Output THDu | <1% , Linear load; <5.5%, Non-linear load | ||||||
| Crest Factor | 3:1 | ||||||
| Inverter Overload | 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms | ||||||
| Battery | Voltage | ±240Vdc | |||||
| Battery Number | 40pcs (Settable: even number from 32 to 44) | ||||||
| Voltage Precision | ±1% | ||||||
| Charge Power | up to 20% * Output active power | ||||||
| Battery Cold Start | Optional | ||||||
| System | Efficiency | AC Mode | 95.0% | 96.0% | |||
| ECO Mode | 98.0% | ||||||
| Battery Mode | 95.0% | 96.0% | |||||
| Display | LCD + LED + keyboard | ||||||
| IP Class | IP 20 | ||||||
| Interface | RS232,RS485 | ||||||
| Option | SNMP Card, Parallel kit, USB, Programmable Dry Contact | ||||||
| Temperature | Operation: 0~40 ℃ Storge: -40~70 ℃ | ||||||
| Relative Humidity | 0~95% Non-condensing | ||||||
| Altitude | <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise | ||||||
| Noise (1 meter) | 55dB @ 50% load | ||||||
| Applicable Standards | Safety: IEC/EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3 | ||||||
| Physical | Weight (kg) | 51.5 | 51.5 | 89 | 89 | 140 | |
| 31 | 31 | 50 | 52 | 61 | |||
| Dimension W*D*H (mm) | 250*840*715 | 250*840*715 | 350*738*1335 | 350*738*1335 | 500*840*1400 | ||
| 250*660*530 | 250*660*530 | 250*680*770 | 250*680*770 | 250*836*770 | |||